Fluke 8845a Service Manual
• ® 8845A/8846A Digital Multimeter Users Manual July 2006, Rev. 2, 6/08 © 2006, 2007, 2008 Fluke Corporation. Specifications subject to change without notice. All rights reserved. All product names are trademarks of their respective companies. • Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke.
8808A Digital Multimeter. Fluke Calibration’s 8808A multimeter is easy to use and. Development and service. CD Rom with user manual (English. View and Download Fluke 8845A user manual online. 8845A Multimeter pdf manual download.
Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. • Table of Contents Chapter Title Page Introduction and Specifications..1-1 Introduction...1-3 Manual Set...1-3 About this Manual... 1-4 Safety Information... 1-4 General Safety Summary..1-4 Symbols...1-6 Instrument Security Procedures..
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information. 8845A/8846A Users Manual 1-4. Order Fluke 8845A/SU 120V on sale from Transcat's 8808A/8845A. Users and Service Manuals (CD-ROM). Fluke 8845A & 8846A User Manual: Fluke 8845A and 8846A.
1-6 Volatile Memory... 1-6 Non Volatile Memory...
• Measurement Rates (IEEE488[4])..1-22 Preparing the Meter for Operation.. 2-1 Introduction...2-3 Unpacking and Inspecting the Meter..2-3 Contacting Fluke...2-3 Storing and Shipping the Meter..
2-3 Power Considerations..2-3 Selecting the Line Voltage..2-4 Replacing the Fuses... • (continued) Contents Controlling System-Related Operations..3-23 Identifying Meter Errors..3-23 Querying the Firmware for Revision Level.. 3-24 Adjusting Display Brightness.. 3-24 Setting the Meter’s Date and Time..3-24 USB Operation...3-24 USB Storage Capacity and Write Time..3-24 USB Memory Device Compatibility and Special Instruction. • 8845A/8846A Users Manual. • Non-volatile Memory Space.. Accessories...1-7 2-1.
Line Voltage to Fuse Rating... Line Power Cord Types Available from Fluke..2-7 3-1. Front-Panel Controls and Connectors..3-4 3-2. Display Elements...3-6 3-3. Rear-Panel Connectors... • 8845A/8846A Users Manual.
Replacing the Line Fuse...2-5 2-2. Replacing the Current Input Fuses.. Line Power Cords Types Available from Fluke.. Bail Adjustment and Removal..2-8 3-1. TrendPlot Display...3-15 3-2. Histogram Display...3-16 4-1.
• 8845A/8846A Users Manual viii. • Chapter 1 Introduction and Specifications Title Page Introduction...1-3 Manual Set...1-3 About this Manual... 1-4 Safety Information... 1-4 General Safety Summary..1-4 Symbols...1-6 Instrument Security Procedures.. 1-6 Volatile Memory... 1-6 Non Volatile Memory...1-7 Media Memory (8846A Only)..
• 8845A/8846A Users Manual Diode Test... 1-22 Measurement Rates (IEEE488[4])..1-22.
Great Little War Game Cracked Pc on this page. • Introduction and Specifications Introduction Introduction The 8845A and 8846A are 6-1/2 digit, dual-display multimeters designed for bench-top, field service, and system applications. Their full complement of measurement functions plus its RS-232, IEEE 488, and Ethernet Remote Interfaces makes these multimeters ideal candidates for precision manual measurements and use in automated systems. • 8845A/8846A Users Manual About this Manual This is the Users Manual for the 8845A and 8846A Digital Multimeters (hereafter referred to as the Meter). It contains all of the information a new user will need to operate the Meter effectively.
The manual is divided into the following chapters: Chapter 1 “Introduction and Specifications”. • Introduction and Specifications Safety Information Table 1-1. Safety Information XW Warning To avoid possible electric shock, personal injury, or death, read the following before using the Meter: Use the Meter only as specified in this manual, or the protection provided by the Meter might be impaired. • Recycle Static awareness. Download 4story Eg Hack Silver Angel. Gentleman Discography. Static discharge Do not dispose of this product as unsorted can damage part(s) municipal waste. Go to Fluke’s website for recycling information.
Instrument Security Procedures This section describes the Meter’s memory elements and the procedures for clearing them. Press the MANAGE MEMORY soft key. Press the ERASE USB MEMORY soft key. Accessories Table 1-5 lists the available accessories for the 8845A and 8846A. Accessories Model/Fluke PN Description TL71 Premium Test Lead Set 6303 Kelvin Probes.
• 8845A/8846A Users Manual Table 1-5. Accessories (cont) Model/Fluke PN Description 884X-Case Black plastic case TL910 Precision Electronic Probe Set TL910 Precision Electronic Probe Set TL80A Basic Electronic DMM Test Set TL2X4W-PTII 2X4 Wire Ohms Test Lead TL2X4W-TWZ 2X4 Wire Ohms SMD Test Tweezer.
• Introduction and Specifications General Specifications Table 1-5. Accessories (cont) Model/Fluke PN Description 1259340 Agreement, Calibration, Accredited 2441827 Agreement, Calibration, primary standards lab 1540600 Agreement, Calibration, artifact General Specifications Power Voltage 100 V Setting..90 V to 110 V 120 V Setting..108 V to 132 V 220 V Setting.. • 8845A/8846A Users Manual Trigger Delay..0 s to 3600 s; in 10 S increments External Trigger Delay.10 G 1.000000 V 100 V 10 V 10 M or >10 G 10 V 10.00000 V 1 mV.